Refine your search
Collections
Co-Authors
Year
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z All
Siva Kumar, R.
- A Validated Reversed Phase HPLC-Method for the Determination of Aceclofenac and Tizanidine in Tablets
Abstract Views :311 |
PDF Views:159
Authors
Source
Asian Journal of Pharmaceutical Research and Health Care, Vol 2, No 1 (2010), Pagination: 84-94Abstract
A new simple, accurate, precise and reproducible Reverse Phase-High Performance Liquid Chromatographic method has been developed for the simultaneous estimation of Aceclofenac and Tizanidine in tablet dosage forms using C18 column (Ineretsil, 250 x 4.6 mm, 5 μm) in isocratic mode. The mobile phase consisted of acetonitrile, methanol and 20 mM phosphate buffer adjusted to pH 3.5 in ratio of (40:30:30 v/v) with Ultraviolet-Visible detection at 230 nm. The method was linear over the concentration range for aceclofenac120-280 μg/ml and for tizanidine 2-40 μg/ml. The recoveries of Tizanidine and Aceclofenac were found to be in the range of 99.45-100.61% and 99.56-101.32% respectively. The validation of method was carried out using International Conference on Harmonization-guidelines. The described High Performance Liquid Chromatographic method was successfully employed for the analysis of pharmaceutical formulations containing combined dosage form.Keywords
Simultaneous Estimation, RP - HPLC, Aceclofenac, Tizanidine, ICH Guidelines.- Evaluation of Standards of Some Selected Cosmetic Preparations
Abstract Views :191 |
PDF Views:136